Key result
MDCT detects LA/LAA thrombus with ~96% sensitivity compared to TEE.
Why the study?
The diagnostic accuracy of multidetector computed tomography (MDCT) for detecting left atrial/left atrial appendage thrombus has been tested in many studies with controversial results.
Does multidetector computed tomography (MDCT) accurately detect left atrial/left atrial appendage thrombus compared to transoesophageal echocardiography (TEE)?
Meta-Analysis (n=2,540)
Does multidetector computed tomography (MDCT) accurately detect left atrial/left atrial appendage thrombus compared to transoesophageal echocardiography (TEE)?
MDCT is a highly accurate alternative to TEE for detecting LA/LAA thrombus, particularly when delayed imaging, ECG gating, and heart rate control are utilized.
Answers are grounded in this paper and cite their sources.
MDCT shows moderate accuracy for LA/LAA thrombus vs TEE, improved by ECG-gating; leaves open routine adoption pending prospective validation.
BACKGROUND: The diagnostic accuracy of multidetector computed tomography (MDCT) in the detection of left atrial/left atrial appendage (LA/LAA) thrombus had been tested in many studies; however, the results are controversial. AIM: The aim of the present study was to evaluate synthetically the diagnostic accuracy of MDCT in LA/LAA thrombus. METHODS: PubMed and Embase were searched for published prospective studies which compared computed tomography with transoesophageal echocardiography (TEE) in detecting LA/LAA thrombus prior to March 2014. Descriptive and quantitative information was extracted and MetaDiSc 1.4 was used to perform a meta-analysis. RESULTS: Fifteen prospective clinical controlled trials with 2540 patients fulfilled the inclusion criteria. The pooled sensitivities (SEN): 0.957; pooled specificities (SPE): 0.917; pooled positive likelihood ratio (PLR): 22.017; pooled negative likelihood ratio (NLR): 0.060; pooled diagnostic odds ratio (DOR): 437.43; the area under the curve (AUC): 0.9883; Q*-value: 0.9544. However, in the abovementioned indexes, the heterogeneities were statistically significant between studies (P < 0.05, inconsistency index (I(2) ) > 50%). In a sub-analysis of studies in which delayed imaging, electrocardiogram (ECG) gating and heart rate control were performed, not only the diagnostic accuracy, but also the heterogeneities were significantly improved (pooled SEN 0.991; pooled SPE 0.989; pooled PLR 60.768; pooled NLR 0.034; pooled DOR 2561.7; AUC 0.9972; Q*-value 0.9806; all the indexes' P-value were greater than 0.05 and the I(2) were 0%, except for SPE, I(2) = 54.6%). CONCLUSION: For patients with TEE intolerance or contraindications, MDCT may be an alternative method, especially when the delayed imaging, ECG gating and heart rate control were performed.
No takes yet. Share an insight, caveat, or question.
Zou et al. (2015) conducted a meta-analysis in Left atrial/left atrial appendage (LA/LAA) thrombus (n=2,540). Multidetector computed tomography (MDCT) vs. Transoesophageal echocardiography (TEE) was evaluated on Diagnostic accuracy for detecting LA/LAA thrombus (DOR 437.43). Multidetector computed tomography demonstrated high diagnostic accuracy for detecting left atrial/left atrial appendage thrombus, with a pooled sensitivity of 0.957 and specificity of 0.917.
Synapse has enriched 10 related papers. Consider them for comparative context: