Both one- and two-stage feed-forward control were applied to α 4-GHz, 461A, traveling-wave tube, used in the TD-3 radio relay system, to demonstrate the feasibility of reducing distortion to a sufficiently low level for single sideband transmission. With a single stage, and discounting extraneous losses, the third-order, MS, distortion measure was reduced by 38 dB over a selected 20-MHz channel, and the application of the second stage rendered distortion unobservable with our instruments. These results were time independent with continuous performance over several months.
No takes yet. Share an insight, caveat, or question.
H. Seidel (1971) studied this question.