Answers are grounded in this paper and cite their sources.
Accurate characterization of the dynamicon-resistance (Rₒₙ) degradation is important to predict conduction losses for gallium nitride (GaN) high-electron-mobility transistors. However, even for the same device, many inconsistent results of dynamic Rₒₙbased on pulsed measurements are reported in the literature. This letter reveals that insufficient test time leads to spurious dynamic Rₒₙresults and even contradictory conclusions. We show that the time required for the dynamic Rₒₙto stabilize can be very long (∼ 3 min) for some commercial GaN devices and pulsed measurements fail to give accurate results. These findings are enabled by our proposed steady-state method using a hard-switching half-bridge with an active measurement circuit. It minimizes the influence of temperature on the Rₒₙ, enabling to capture trap-related effects independently from the operation conditions. This letter raises awareness of the effect of poorly measured dynamic Rₒₙand highlights that steady-state methods should be applied for accurate measurements to predict their performance in real power converter operations.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: