Key result
Implantable loop recorders detect paroxysmal AF in ~33% of poorly performing racehorses.
Why the study?
Paroxysmal atrial fibrillation in horses is difficult to diagnose due to its intermittent occurrence, and the potential of subcutaneous implantable loop recorders for continuous automatic detection in horses with poor performance required investigation.
Can subcutaneously implanted loop recorders detect paroxysmal atrial fibrillation in Standardbred racehorses presenting with intermittent poor performance?
Cohort (n=12)
Can subcutaneously implanted loop recorders detect paroxysmal atrial fibrillation in Standardbred racehorses presenting with intermittent poor performance?
Implantable loop recorders can successfully detect paroxysmal atrial fibrillation in one-third of racehorses with unexplained intermittent poor performance, though manual ECG review is required due to a 54% false-positive detection rate.
Answers are grounded in this paper and cite their sources.
ILRs may aid paroxysmal AF detection in poor-performing racehorses; leaves open validation and outcome impact in larger prospective studies.
BACKGROUND: Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. OBJECTIVES: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. STUDY DESIGN: Prospective field study. METHODS: Twelve racing Standardbred trotters with intermittent reduced performance (mean age: six years) were enrolled prospectively. The ILR was implanted subcutaneously at the fifth or sixth left intercostal space and data from the ILR was collected during the study period in which the horses were followed for a median duration of 7.5 month (range 6-28). RESULTS: The ILR was able to detect PAF in four out of twelve racehorses. The ILR also detected sustained atrial fibrillation (AF) in one horse during the study. The ILRs rely on RR detection and R waves were correctly identified in 96%. One hundred episodes were categorised as AF by the ILRs and subsequently visual ECG inspection categorised 12 as sinus rhythm (SR), 28 as sinus arrhythmia (SA), 14 as other arrhythmias and 46 as AF episodes. The Root Mean Square of the Successive Differences (RMSSD) values were significantly increased for AF compared to SR and SA. MAIN LIMITATIONS: Few horses included and duration of study period varied among the horses. Further it was not possible to assess the sensitivity of the device in the current study and the ILRs proved to have a high rate of false positive misclassifications. CONCLUSIONS: This study indicates that ILRs can be used for detection of PAF episodes and could be a useful ECG tool for horses presenting with poor performance. This methodology provides a platform to facilitate the long-term assessment of AF development and quantification of AF burden in horses. Further studies including both healthy and poor performing horses are needed in order to learn more about PAF prevalence in racehorses.
No takes yet. Share an insight, caveat, or question.
Buhl et al. (2020) conducted a cohort in Paroxysmal atrial fibrillation and intermittent poor performance in Standardbred racehorses (n=12). Implantable loop recorder (Medtronic Reveal LINQ) vs. Visual ECG inspection was evaluated on Detection of paroxysmal atrial fibrillation (PAF) and accuracy of automatic AF episode classification confirmed by visual ECG inspection. Implantable loop recorders detected paroxysmal atrial fibrillation in 4 of 12 poor-performing racehorses and correctly classified 46 of 100 suspected AF episodes.