Answers are grounded in this paper and cite their sources.
Due to the recent increase in clinical trials investigating intravenous vitamin C as a potential therapy in critically ill patients with sepsis and septic shock, safety issues have been raised.It is well known that high (10-110 g) doses of intravenous vitamin C, typically administered to oncology patients and patients with severe burns, can interfere with some point-of-care glucose meters, particularly if measured during or immediately after the intravenous vitamin C infusion.1,2 Therefore, caution is required for patients needing regular glucose monitoring.However, it is less certain whether the lower (1.5 g or 25 mg/kg every 6 hours) doses of intravenous vitamin C that are typically administered to critically ill patients interfere to the same extent.Preliminary evidence indicates that critically ill patients with renal impairment (oliguria) may exhibit spuriously high point-of-care glucose values following low dose intravenous vitamin C infusion.[3][4][5] Intravenous vitamin C can interfere with many point-ofcare glucose meters, even at low gram doses.6 Point-ofcare glucose meters utilise a variety of different detection methods, including electrochemical detection using glucose dehydrogenase or glucose oxidase.6 Vitamin C can donate up to two electrons per molecule and potentially elevate point-of-care readings, depending on the biochemistry used in the monitor.Intravenous vitamin C, however, does not interfere with the laboratory-based hexokinase method, which uses spectrophotometric rather than electrochemical detection.2,5,6 In this study, we aimed to determine the concentrations at which ascorbate begins to interfere with the Accu-Chek Inform II (Roche Diagnostics, USA) point-of-care glucose meter (which utilises glucose dehydrogenase amphoteric detection) using three different baseline glucose concentrations.We also compared matched arterial blood samples tested with the Accu-Chek, an arterial blood gas (ABG) analyser located in the intensive care unit, and the laboratory glucose method in septic patients receiving intravenous vitamin C infusions (at a dose of 25 mg/kg every 6 hours) with measured plasma vitamin C concentrations.Finally, we utilised the surveillance error grid analysis to ABSTRACT Background: Intravenous vitamin C is known to interfere with some point-of-care blood glucose meters.We aimed to determine the concentrations at which ascorbate interferes with glucose concentrations measured using a point-ofcare blood glucose meter.We also compared the point-ofcare meter and an arterial blood gas (ABG) analyser in the intensive care unit with laboratory glucose monitoring in septic patients receiving intravenous vitamin C infusions.Methods: Blood samples containing normal, depleted and supplemented glucose and increasing concentrations of ascorbate (0.1-1.0 mmol/L) were tested using an Accu-Chek Inform II (Roche Diagnostics, USA) glucometer.For the in vivo study, 41 individual blood samples were drawn daily from septic patients (n = 16) receiving infusions of 25 mg/kg of vitamin C every 6 hours.The glucose values of matched blood samples were assessed using Accu-Chek, ABG and laboratory glucose methods.Results: For every 1 mmol/L of ascorbate added, the glucose concentration measured by the point-of-care monitor increased by 1.4 mmol/L (95% CI, 1.0-1.8;P < 0.001).Analysis of matched blood samples collected following intravenous vitamin C infusion indicated that 98% of the ABG and 83% of the Accu-Chek values met the International Organization for Standardization (ISO) 15197:2013 accuracy criteria.One patient had severe renal impairment, which contributed to elevated plasma vitamin C concentrations (median, 0.95 mmol/L; range, 0.64-1.10mmol/L), resulting in elevated Accu-Chek readings and presenting a moderate clinical risk for the highest value.Conclusions: Vitamin C concentrations < 0.8 mmol/L do not interfere with point-of-care glucose monitoring.Intravenous vitamin C infusion of 25 mg/kg every 6 hours does not interfere with point-of-care glucose monitoring unless the patient has renal impairment, in which case laboratory glucose tests should be used.
No takes yet. Share an insight, caveat, or question.
Rosengrave et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: