Key result
Composite bioconduit shows no benefit over root preservation for mortality or structural valve deterioration.
Why the study?
The effect of sinuses of Valsalva on aortic bioprosthesis durability has not been investigated so far.
Does aortic valve and ascending aorta replacement as a composite bioconduit affect prosthesis durability compared to separate replacement with preservation of the aortic root in patients receiving a Carpentier-Edwards bioprosthesis?
Cohort (n=295)
Does aortic valve and ascending aorta replacement as a composite bioconduit affect prosthesis durability compared to separate replacement with preservation of the aortic root in patients receiving a Carpentier-Edwards bioprosthesis?
The absence of sinuses of Valsalva in composite bioconduits does not appear to compromise the durability of Carpentier-Edwards aortic bioprostheses up to 12 years.
Answers are grounded in this paper and cite their sources.
No impact of sinuses of Valsalva on Carpentier-Edwards bioprosthesis durability seen to 12 years; leaves open whether longer follow-up reveals differences.
OBJECTIVES: The effect of sinuses of Valsalva on aortic bioprosthesis durability has not been investigated so far. The aim of this study was to compare durability of the Carpentier-Edwards aortic bioprosthesis in patients undergoing aortic valve and ascending aorta replacement as a composite bioconduit (Group A, case group) versus patients undergoing separate replacement of the aortic valve and ascending aorta, with preservation of the aortic root (Group B, control group), between January 2000 and January 2014. METHODS: Records of Group A (n = 133) and Group B (n = 162) patients were retrospectively reviewed. End-points were evaluated among groups in three ways: before and after propensity score 1:1 matching (Group A, n = 94; Group B, n = 94 patients) and after patient stratification through quintiles of propensity scores. RESULTS: There was no difference among groups regarding mean and maximal trans-prosthetic pressure gradients at discharge (P = 0.07 and 0.45, respectively). Maximal trans-prosthetic gradients were lower in Group A patients at last control (P = 0.03). Structural valve deterioration (SVD) was due to prosthesis regurgitation (Group A, n = 5; Group B, n = 1), stenosis (Group A, n = 2; Group B, n = 5) or combined (Group A, n = 4; Group B, n = 2). After a mean follow-up of 68 ± 42 months, there was no difference among groups, at 5 and 12 years, regarding mortality, freedom from SVD, from redo aortic valve replacement for SVD and cardiac redo of any type, before and after matching and after stratification according to quintiles of propensity scores. CONCLUSIONS: Within the 12-year follow-up, the absence of the sinuses of Valsalva seems to have no influence on durability of Carpentier Edwards aortic bioprosthesis. Longer follow-up may be warranted.
No takes yet. Share an insight, caveat, or question.
Ius et al. (2015) conducted a cohort in Aortic valve and ascending aorta replacement (n=295). Aortic valve and ascending aorta replacement as a composite bioconduit vs. Separate replacement of the aortic valve and ascending aorta with preservation of the aortic root was evaluated on Mortality, freedom from structural valve deterioration, redo aortic valve replacement for SVD, and cardiac redo of any type. After a mean follow-up of 68 months, aortic valve and ascending aorta replacement as a composite bioconduit showed no difference in mortality or structural valve deterioration versus root preservation.