Key result
Percutaneous transaxillary access for TAVR utilizes axillary arteries, which are less calcified and usually have luminal diameters >5.0 mm even when iliofemoral arteries are <5.0 mm.
Answers are grounded in this paper and cite their sources.
Percutaneous transaxillary access provides a viable non-surgical option for large-bore arterial access in TAVR when iliofemoral access is unsuitable.
Axillary arteries are less calcified and tortuous than iliofemoral arteries Axillary artery minimal luminal diameters are usually >5.0 mm even in patients with iliofemoral artery diameters < 5.0 mm Axillary and transcaval access are the only non-surgical fully percutaneous options for large-bore arterial access for TAVR or mechanical circulatory support devices.
No takes yet. Share an insight, caveat, or question.
Rogers et al. (2018) studied this question. Percutaneous transaxillary access for TAVR utilizes axillary arteries, which are less calcified and usually have luminal diameters >5.0 mm even when iliofemoral arteries are <5.0 mm.
Synapse has enriched 10 related papers. Consider them for comparative context: