In this research, we report the preparation of a high sensitive voltammetric sensor for electrocatalytic determination of hydroxylamine (HX) in the presence of thiosulfate (TS). We describe the synthesis and characterization of CdO nanoparticles (CdO/NPs) with transmission electron microscopy (TEM) and X‐ray diffraction (XRD) methods. At an optimum condition, the two peaks are separated ca. 0.58 and 0.92 V for HX and TS at the surface of the proposed sensor. Square wave voltammetry (SWV) of HX exhibited two linear dynamic ranges with a detection limit (3σ) of 0.06 µmol L−1. The propose sensor was used for determination of HX in water samples.
No takes yet. Share an insight, caveat, or question.
Shabani‐Nooshabadi et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: