Answers are grounded in this paper and cite their sources.
As peritoneal dialysis (PD)-related fungal infection is associated with a high mortality rate, the international guidelines recommend immediate removal of the PD catheter in conjunction with at least 2-weeks of antifungal treatment. Some authors have reported successful management of such cases without removing the PD catheter - by instilling an antifungal lock into the retained PD catheter. However, the use of antifungal locks has generally not been well accepted as the standard treatment for fungal peritonitis in PD patients. We report two cases where antifungal lock were performed in PD patients presented with PD-related fungal infection that not only had no effect on abating the infection but also causing paradoxical outcomes.
No takes yet. Share an insight, caveat, or question.
Puapatanakul et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: