Key result
Inhaled pulmonary vasodilators for PPHN risk rebound pulmonary hypertension without consistent delivery systems.
Why the study?
What are the safety issues relating to drug administration and delivery devices for inhaled pulmonary vasodilators in neonates with PPHN?
What are the safety issues relating to drug administration and delivery devices for inhaled pulmonary vasodilators in neonates with PPHN?
The use of consistent delivery systems with safety features is crucial when administering inhaled pulmonary vasodilators for PPHN to prevent rebound pulmonary hypertension.
Supports consistent delivery systems to mitigate rebound risk in PPHN; leaves open device standardization for prospective validation.
Treatment for persistent pulmonary hypertension of the newborn (PPHN) aims to reduce pulmonary vascular resistance while maintaining systemic vascular resistance. Selective pulmonary vasodilation may be achieved by targeting pulmonary-specific pathways or by delivering vasodilators directly to the lungs. Abrupt withdrawal of a pulmonary vasodilator can cause rebound pulmonary hypertension. Therefore, use of consistent delivery systems that allow for careful monitoring of drug delivery is important. This manuscript reviews published studies of inhaled vasodilators used for treatment of PPHN and provides an overview of safety issues associated with drug delivery and delivery devices as they relate to the risk of rebound pulmonary hypertension. Off-label use of aerosolized prostacyclins and an aerosolized prostaglandin in neonates with PPHN has been reported; however, evidence from large randomized clinical trials is lacking. The amount of a given dose of aerosolized drug that is actually delivered to the lungs is often unknown, and the actual amount of drug deposited in the lungs can be affected by several factors, including patient size, nebulizer used, and placement of the nebulizer within the breathing circuit. Inhaled nitric oxide (iNO) is the only pulmonary vasodilator approved by the US Food and Drug Administration for the treatment of PPHN. The iNO delivery device, INOmax DSIR®IR, is designed to constantly monitor NO, NO2, and O2 deliveries and is equipped with audible and visual alarms to alert providers of abrupt discontinuation and incorrect drug concentration. Other safety features of this device include two independent backup delivery systems, a backup drug cylinder, a battery that provides up to 6 hours of uninterrupted medication delivery, and 27 alarms that monitor delivery, dosage, and system functions. The ability of the drug delivery device to provide safe, consistent dosing is important to consider when selecting a pulmonary vasodilator.
No takes yet. Share an insight, caveat, or question.
Cosa et al. (2016) conducted a review in persistent pulmonary hypertension of the newborn (PPHN). Inhaled pulmonary vasodilators was evaluated. This review highlights safety issues of inhaled pulmonary vasodilators for PPHN, emphasizing that consistent delivery systems are crucial to prevent rebound pulmonary hypertension.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: