The paper describes the distinctive features of the pseudo‐dynamic test method as implemented at the largest European reaction‐wall facility. Both hardware and software aspects are considered. Particular attention is devoted to the digital control system and to the time integration algorithms. A test‐restart procedure well suited for stiff/brittle structures and a coupled numerical‐experimental substructuring technique allowing realistic earthquake testing of very large structures are included. Finally a prospective view of continuous pseudo‐dynamic testing is introduced. Selected test results illustrate the advantages of the presented features.
No takes yet. Share an insight, caveat, or question.
Donéa et al. (1996) studied this question.