Answers are grounded in this paper and cite their sources.
A two-Kelvin-probe arrangement was used to measure, for the first time in situ , the work functions, Φ, of the gas-exposed surfaces of porous Pt, Au, and Ag working and reference electrodes exposed to and mixtures, and deposited on 8% -stabilized (YSZ) in a three-electrode solid electrolyte cell. It was found that at temperatures above 600 K the potential difference, between the working (W) and reference (R) electrode reflects the difference in the actual, spillover, and adsorption-modified work functions, and of the two electrodes This equation, typically valid over 0.8-1 V wide ranges, was found to hold for any combination of the Pt, Au, and Ag electrodes. It is consistent with the previously reported equation which is also confirmed here, and allows for the definition of a natural absolute electrode potential in solid-state electrochemistry from where Φ is the work function of the gas-exposed electrode surface of the metal (any metal) electrode in contact with the YSZ solid electrolyte. It expresses the energy of solvation of an electron from vacuum to the Fermi level of the solid electrolyte. The value V was determined as the standard value at and K.
No takes yet. Share an insight, caveat, or question.
Tsiplakides et al. (2001) studied this question.