Key result
NMSR improves registration accuracy for dense myocardial and blood flow tracking versus ANTs and VoxelMorph.
Why the study?
Manual measurement of myocardial motion and blood flow from echocardiography is time-consuming and error-prone, while automated algorithms face challenges from noise and high image variability.
Does the NMSR method improve registration accuracy for echocardiogram dense tracking compared to existing methods?
Does the NMSR method improve registration accuracy for echocardiogram dense tracking compared to existing methods?
The proposed NMSR method provides a fully automated approach that improves registration accuracy for fast and accurate analyses of echocardiograms.
Answers are grounded in this paper and cite their sources.
May support faster echocardiogram analyses; leaves open prospective validation for clinical use.
Echocardiography has become routinely used in the diagnosis of cardiomyopathy and abnormal cardiac blood flow. However, manually measuring myocardial motion and cardiac blood flow from echocardiogram is time-consuming and error-prone. Computer algorithms that can automatically track and quantify myocardial motion and cardiac blood flow are highly sought after, but have not been very successful due to noise and high variability of echocardiography. In this work, we propose a neural multi-scale self-supervised registration (NMSR) method for automated myocardial and cardiac blood flow dense tracking. NMSR incorporates two novel components: 1) utilizing a deep neural net to parameterize the velocity field between two image frames, and 2) optimizing the parameters of the neural net in a sequential multi-scale fashion to account for large variations within the velocity field. Experiments demonstrate that NMSR yields significantly better registration accuracy than state-of-the-art methods, such as advanced normalization tools (ANTs) and VoxelMorph, for both myocardial and cardiac blood flow dense tracking. Our approach promises to provide a fully automated method for fast and accurate analyses of echocardiograms.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2019) studied Echocardiogram tracking (myocardial and cardiac blood flow) (n=90). Neural Multi-Scale Self-Supervised Registration (NMSR) vs. Advanced Normalization Tools (ANTs) and VoxelMorph was evaluated on Registration accuracy measured by Mean Square Error (MSE) and Mean Local Cross Correlation (Mean CC). The proposed Neural Multi-Scale Self-Supervised Registration (NMSR) method yielded better registration accuracy for myocardial and cardiac blood flow dense tracking compared to ANTs and VoxelMorph.
Synapse has enriched 10 related papers. Consider them for comparative context: