S-Enalapril, and S-ramipril are angiotensin-converting enzyme (ACE) inhibitors which are used for treatment of hypertension. Due to the fact that only the S enantiomer possesses the ACE inhibiting activity, it is necessary to develop an enantioselective analytical method for its discrimination from the less active R-enantiomer. An amperometric biosensor, based on L-amino acid oxidase, was developed and proved reliable for the analysis of the S-enantiomer of these ACE inhibitors. The working range of the biosensor for S-enalapril assay (A) is 0.4-120 mumol/L, and for S-ramipril assay (B) is 0.2-100 mumol/L, with a limit of detection of 163 nmol/L (A) and 107 nmol/L (B), respectively. It is of interest to mention that the biosensors demonstrated enantioselectivity versus D-proline (1.4 x 10(-3) mol/L(A), 5.3 x 10(-3) mol/L(B) and also the selectivity versus the polyvinylpyrolidone (3.0 x 10(-3) mol/L(A), 3.2 x 10(-3) mol/L(B), respectively. The working pH ranges are: 6.8-7.4 (A), and 6.2-7.0 (B), respectively. The RSD < 1% assured by using the amperometric biosensors for S enantiomers assay in raw materials, in tablet formulations, and their suitability for the analysis of these drug enantiomers.
No takes yet. Share an insight, caveat, or question.
Staden et al. (1998) studied this question.