Purpose: To evaluate hemodynamic changes during on-day vitrectomy for elderly patients referred during cataract surgery.Methods: This retrospective study included 10 patients (85 years or older) referred during cataract surgery who underwent same-day vitrectomy.Blood pressure (BP) and pulse rate measured in the ward were compared with those measured immediately preoperative in the operating room, and the highest values were measured during surgery.Results: Mean age of the patients was 88.9 ± 3.4 years.In the ward, the mean systolic and diastolic BP was 150.0 ± 16.3 mmHg and 80.0 ± 8.2 mmHg, respectively, and pulse rate was 78.5 ± 13.6.The same values measured immediately preoperative were 158.0 ± 15.7 mmHg, 79.5 ± 5.9 mmHg, and 74.1 ± 10.3, respectively, and the highest values during the operation were 159.8 ± 12.8 mmHg, 82.8 ± 6.9 mmHg, and 83.9 ± 13.9, respectively.The highest systolic BP during surgery was significantly higher than that measured in the ward (p = 0.038).However, the difference between intraoperative BP and that measured right before surgery was not significant (p = 1.000).Diastolic BP and pulse rate did not vary among the three time points. Conclusions:The results of the present study indicate that BP can increase during on-day vitrectomy even when BP is not high in the ward and suggests the need for careful BP monitoring during vitrectomy.