Answers are grounded in this paper and cite their sources.
Demonstrates synchronous spectrofluorimetry for simultaneous quantification of bisoprolol and amlodipine in tablets and plasma, indicating a sustainable method for quality control.
In this study, we present a direct, sensitive, and green spectrofluorimetric approach for simultaneous measurement of bisoprolol fumarate (BSL) and amlodipine besylate (AMD) in their tablets and plasma. This approach measures the synchronized fluorescence intensity of the two drugs at Δ λ of 55 nm with λ max captured at 265 and 375 nm for BSL and AMD, respectively. The method is linear over the concentration range of 0.1–4.1 μg/mL for BSL and 1.0–9.0 μg/mL for AMD. The limit of detection for BSL and AMD is 0.0168 and 0.1227, and the limit of quantification is 0.0508 and 0.3717 μg/mL, respectively. This technique is effectively used to analyze the two studied drugs in their tablets with high %Recoveries of 100.09% for BSL and 99.67% for AMD and %RSD ≤ 1.54. The proposed technique is verified in compliance with the ICH Q2(R2) criteria. Hence, the suggested spectrofluorimetric approach effectively assesses the content uniformity of their tablets in accordance with the British Pharmacopoeia. Besides, BSL is determined in plasma over the range of 0.1–0.5 μg/mL with high percentage recoveries (98.95%–101.60%) and low %RSD values (1.326). The greenness of the developed method was positively assessed using three distinct green metrics, including AGREE, GAPI, and BAGI.
No takes yet. Share an insight, caveat, or question.
Kamel et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: