Answers are grounded in this paper and cite their sources.
The escalating operating frequencies and packaging densities of modern printed circuit boards (PCBs) demand stringent electromagnetic interference (EMI) shielding solutions to comply with electromagnetic compatibility (EMC) regulations and suppress internal noise. A widely adopted strategy employs metallic enclosures with multi-cavity designs, which are bonded to the PCB ground plane via EMI gaskets. This paper introduces an innovative cavity-to-cavity measurement methodology employing opposite-side monopole probes to evaluate the shielding effectiveness (SE) of gasket under test. A test fixture comprising two adjacent symmetrical cavities (30 mm × 15 mm × 3 mm) interconnected by the gasket under test is used to simulate the real application conditions of a board-level shield, through which the SE from 10 to 40 GHz can be measured based on scattering parameters between probe pins on opposite sides. Comparative analysis reveals that opposite-side probing yields SE measurements with significantly improved accuracy over conventional same-side probing configurations, as reduced probe coupling more accurately represents the gasket’s intrinsic SE. The proposed method establishes a robust and precise framework for high-frequency gasket evaluation up to frequencies beyond 40 GHz, effectively addressing limitations inherent in existing cavity-to-cavity techniques.
No takes yet. Share an insight, caveat, or question.
Han et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: