1,2-4 Triazole (TAZ), N-lauroylsarcosine sodium salt (NLS) and potassium oleate (PO) were tested as passivating additives to previously developed H 2 O 2 and citric acid-based silica dispersions for the polishing of chemical vapor deposited Co films for interconnect applications. In comparison to TAZ and NLS, Co corrosion currents are ∼1 to 2 order of magnitude lower (∼1–3 μA cm −2 ) at pH 7 with PO and post-polish surface quality was much better. The galvanic corrosion currents between Co-Ti and Ti-TiN couples with PO were also very low (∼0.1 μA cm −2 ), making the previously developed silica and citric acid-based dispersion, now containing PO, suitable for both bulk removal of Co (step I) and for planarizing Co/Ti/TiN structures (step II) with excellent selectivity while stopping on low-k dielectric. Langmuir adsorption isotherm model analysis showed that the standard free energies of adsorption values were ∼−40 kJ/mol for PO suggesting chemisorption. Fourier transform infra-red (FTIR) and attenuated FTIR spectroscopy data show bridging coordination between the carboxylate ligand of PO and the Co surface.
No takes yet. Share an insight, caveat, or question.
Popuri et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: