Key result
Sonographic IVC diameter and collapsibility strongly correlate with CVP, especially in spontaneously breathing patients.
Why the study?
The study sought to determine the correlation of sonographic inferior vena cava diameter and collapsibility index with central venous pressure in spontaneously breathing and mechanically ventilated surgical ICU patients.
Does sonographic evaluation of IVC diameter and collapsibility index correlate with central venous pressure in critically ill patients?
Cross-Sectional (n=126)
No
Does sonographic evaluation of IVC diameter and collapsibility index correlate with central venous pressure in critically ill patients?
Answers are grounded in this paper and cite their sources.
Sonographic evaluation of IVC diameter and collapsibility index is a reliable, non-invasive method to assess intravascular volume status, particularly in spontaneously breathing critically ill patients.
OBJECTIVE: To determine the correlation of sonographic evaluation of inferior vena cava diameter and its collapsibility index with central venous pressure in both spontaneously breathing and mechanically ventilated patients in surgical ICU. Study Design: Cross-sectional study. PLACE AND DURATION OF STUDY: Surgical ICU, Lahore General Hospital from November 2020 to May 2021. METHODOLOGY: All patients above 18 years of age, who had central venous catheter placed, were included in the study. Patients with raised abdominal pressure, pregnancy, morbid obesity, heart diseases, and those unable to lie in supine position, were excluded. For inferior vena cava (IVC) measurement, IVC was visualised using curvilinear probe of ultrasound machine. Minimum and maximum diameters of inferior vena cava were calculated in every respiratory phase. IVC collapsibility index was expressed in percentage. Central venous pressure (CVP) was recorded soon after IVC measurement, using manometer. RESULTS: Total number of patients was 126. A significant correlation was seen between IVC measurements (inferior vena cava diameters and the collapsibility index) and CVP, (p<0.001), but the regression coefficients were less in patients who were mechanically ventilated (r=0.779 for IVC maximum diameter and -0.725 for collapsibility index) than the patients who were breathing spontaneously (r=0.850 for IVC maximum diameter and -0.899 for collapsibility index) Conclusion: Evaluation of IVC diameter and its collapsibility index is an easy and non-invasive method to evaluate intravascular volume status of critically ill patients. Its use is more helpful in patients who are spontaneously breathing than those who are mechanically ventilated.
No takes yet. Share an insight, caveat, or question.
Afia Arshed Dodhy (2021) conducted a cross-sectional in Critically ill patients in surgical ICU (n=126). Sonographic evaluation of inferior vena cava diameter and collapsibility index was evaluated on Correlation with central venous pressure (r=0.850 (max diameter) and r=-0.899 (collapsibility) in spontaneously breathing; r=0.779 and r=-0.725 in mechanically ventilated, p=<0.001). Sonographic evaluation of inferior vena cava diameter and collapsibility index correlated with central venous pressure, with stronger correlation in spontaneously breathing patients.