Key result
Small gestational sac size predicts a ~94% spontaneous abortion rate despite normal fetal cardiac activity.
Why the study?
Criteria for predicting impending first-trimester pregnancy loss despite normal fetal heart rate were not established.
Does a small sac size predict spontaneous abortion in first-trimester pregnancies with normal fetal cardiac activity?
Cohort (n=68)
Does a small sac size predict spontaneous abortion in first-trimester pregnancies with normal fetal cardiac activity?
A small sac size in the first trimester is highly predictive of spontaneous abortion despite the presence of normal fetal cardiac activity.
Answers are grounded in this paper and cite their sources.
May support closer surveillance of first-trimester pregnancies with small sacs despite normal cardiac activity; leaves open prospective validation before changing practice.
A nonbradycardiac fetal heart rate is associated with a low rate of spontaneous abortion (2%-4%). To determine criteria for predicting impending first-trimester loss when a normal fetal heart rate is identified sonographically, the authors studied 16 consecutively examined patients with pregnancies of 5.5-9 weeks gestation, a small sac size, and fetuses with normal cardiac activity. Mean sac size (MSS) was determined and a small sac was diagnosed when the difference between the MSS and crown-rump length (MSS--CR) was less than 5 mm. Fifty-two consecutively examined patients with pregnancies of 5.5-9 weeks gestation, normal sac size, and fetuses with normal heart rate formed the control group. An MSS--CR of 5 mm or greater was considered normal. Fifteen of the 16 patients (94%) with first-trimester small sacs had spontaneous abortions despite normal sonographic cardiac activity. Four of the 52 control patients (8%) with normal sac sizes had spontaneous abortions. The authors' data show that, despite the presence of fetal cardiac activity at the time of sonography, the usual reassurance provided to patients should be guarded when the sac size is small.
No takes yet. Share an insight, caveat, or question.
Bromley et al. (1991) conducted a cohort in First-trimester pregnancy (n=68). Small sac size (MSS - CR < 5 mm) vs. Normal sac size (MSS - CR ≥ 5 mm) was evaluated on Spontaneous abortion. A small gestational sac size (MSS-CR < 5 mm) was associated with a 94% rate of spontaneous abortion compared to 8% with normal sac sizes, despite normal fetal cardiac activity.
Synapse has enriched 10 related papers. Consider them for comparative context: