The influence of incomplete ionization of dopants in 4H/6H-SiC on transient device behavior has been investigated numerically based on a self-consistent solution of the coupled system of Poisson's equation, the continuity equations of electrons and holes, and balance equations for each donor or acceptor level. If the rise time of a reverse bias pulse is equal or smaller than the characteristic ionization time constant, a dynamically enlarged extension of depletion regions is obtained which can result in a dynamic punchthrough (PT) within back-to-back junction configurations. The respective time constants of nitrogen (N), aluminum (Al), and boron (B) mere measured as functions of temperature in 4H- and 6H-SiC using thermal admittance spectroscopy (AS) and deep level transient spectroscopy (DLTS). At room temperature, for instance, we obtained 60 ps/2 ps, 300 ps/10 ps, and 100 ns/100 ns for N (cubic site), Al, and B in 4H/6H-SiC, respectively. As the time constants of N and Al are small, transient incomplete ionization turns out to be negligible, at least within today's high-power device operation areas. Boron, on the other hand, influences significantly the dynamic device characteristics. In order to demonstrate the implications of these effects, numerical device simulations of a 6H-SiC double-implanted MOSFET and a 4H-SiC thyristor were performed. These simulations allow a detailed analysis of the transient device behavior and the onset of dynamic PT which strongly depends on temperature, structure parameters, and the external excitation.
No takes yet. Share an insight, caveat, or question.
Lades et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: