Key result
Automated threshold-based artefact removal improves neonatal sleep classifier accuracy by ~29%.
Why the study?
Visual artefact removal in neonatal EEG is operator-dependent, time-consuming, and inconsistent, creating a need for automated detection and removal of flat line segments and large amplitude fluctuations.
Does a threshold-based algorithm improve artefact removal and sleep classification performance in neonatal EEG?
Does a threshold-based algorithm improve artefact removal and sleep classification performance in neonatal EEG?
The proposed threshold-based algorithm effectively removes flat line and large amplitude artefacts from neonatal EEG, significantly improving the performance of automated sleep classification.
May enhance automated neonatal EEG staging; leaves open prospective clinical validation before practice adoption.
Background: Artefact removal in neonatal electroencephalography (EEG) by visual inspection generally depends on the expertise of the operator, is time consuming and is not a consistent pre-processing step to the pipeline for the automated EEG analysis. Therefore, there is the need for the automated detection and removal of artefacts in neonatal EEG, especially of distinct and predominant artefacts such as flat line segments (mainly caused by instrumental error where contact between electrodes and head box is lost) and large amplitude fluctuations (related to neonatal movements). Method: A threshold-based algorithm for the automated detection and removal of flat line segments and large amplitude fluctuations in neonatal EEG of infants at term-equivalent age is developed. The algorithm applies thresholds to the absolute second difference, absolute amplitude, absolute first difference and the ratio between the frequency content above 50 Hz and the frequency content across all frequencies. Results: The algorithm reaches a median accuracy of 0.91, a median hit rate of 0.91 and a median false discovery rate of 0.37. Also, a significant improvement (≈10%) in the performance of a four-stage sleep classifier is observed after artefact removal with the proposed algorithm as compared to before its application. Significance: An automated artefact removal method contributes to the pipeline of automated EEG analysis. The proposed algorithm has shown to have good performance and to be effective in neonatal EEG applications.
No takes yet. Share an insight, caveat, or question.
Tamburro et al. (2022) studied Neonatal electroencephalography (EEG) monitoring (n=47). Automated threshold-based algorithm for artefact removal vs. Before artefact removal was evaluated on Accuracy of a four-stage sleep classifier (using 3-s window) (p=0.0044). Application of the automated threshold-based artefact removal algorithm significantly improved the accuracy of a neonatal four-stage sleep classifier from 39.05% to 50.22%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: