An important element for the analysis of the electromagnetic conducted emissions in railway traction systems is the line impedance Z at the pantograph terminals. Simplified expressions of Z are derived under various assumptions, and their validity is checked against an analytically derived reference expression. A sensitivity analysis of Z is performed with respect to some electrical parameters of the traction line. The influence of the substation impedance as a terminal condition for the traction line is considered for dc substations; several substation configurations (rated power and filter characteristics) in use in different countries are considered.
No takes yet. Share an insight, caveat, or question.
Mariscotti et al. (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: