Piezoresistive stress sensors on the (111) surface of silicon offer the unique ability to measure the complete stress state at a point in the (111) material. However, four-point bending or wafer-level calibration methods can measure only four of the six piezoresistive coefficients for p- and n-type resistors required for application of these sensors. In this work, a hydrostatic test method has been developed in which a high-capacity pressure vessel is used to apply a triaxial load to a single die over the -25degC to+100 degC temperature range. The slopes of the adjusted resistance change versus pressure plots yield pressure coefficients for p- and n-type silicon that provide the additional information necessary to fully determine the complete set of piezoresistive coefficients.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: