Answers are grounded in this paper and cite their sources.
This study presents a novel and efficient methodology for the preliminary seismic assessment of existing steel high-rise structures, eliminating the need for computationally intensive nonlinear analyses. The proposed framework integrates three key innovations: (1) a stiffness-based moment distribution model that links beam yielding to column capacities, (2) failure-mode-dependent reduction factors (β=0.7−0.9 for strength; γ=0.6−0. 8 for ductility) that penalize non-ductile mechanisms, and (3) a systematized adjustment factor (Q) that quantifies the detrimental effects of structural irregularities and material degradation. The methodology was validated through application to an 18-story steel moment-resisting frame (SMRF). Results revealed a critical soft-story vulnerability, with a seismic index of IS=92.5<100, whereas a conventional capacity–demand ratio (E=1.14) incorrectly suggested adequacy. This demonstrates the superior diagnostic capability of the proposed approach in capturing system-level deficiencies overlooked by traditional methods. By aligning with ASCE 41–23 provisions, the framework provides both computational efficiency and diagnostic precision, making it highly suitable for rapid screening of large building inventories. Its ability to prioritize retrofit needs offers significant value for urban seismic risk management and resilience planning.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: