Key result
Calibrated image-derived input functions yield unbiased glucose uptake rates without blood sampling.
Why the study?
Does a simple calibration method for image-derived input functions (IDIFs) improve the accuracy of calculating the metabolic uptake rate of glucose from [18F]-FDG PET scans compared to arterial blood sampling?
Does a simple calibration method for image-derived input functions (IDIFs) improve the accuracy of calculating the metabolic uptake rate of glucose from [18F]-FDG PET scans compared to arterial blood sampling?
A simple calibration procedure can remove bias from image-derived input functions in [18F]-FDG PET, potentially obviating the need for arterial blood sampling.
Supports noninvasive FDG-PET glucose uptake quantification without arterial sampling; leaves open prospective validation before clinical adoption.
PURPOSE: We investigated the use of a simple calibration method to remove bias in previously proposed approaches to image-derived input functions (IDIFs) when used to calculate the metabolic uptake rate of glucose (K(m)) from dynamic [(18)F]-FDG PET scans of the thigh. Our objective was to obtain nonbiased, low-variance K(m) values without blood sampling. MATERIALS AND METHODS: We evaluated eight previously proposed IDIF methods. K(m) values derived from these IDIFs were compared with Km values calculated from the arterial blood samples (gold standard). We used linear regression to extract calibration parameters to remove bias. Following calibration, cross-validation and bootstrapping were used to estimate the mean square error and variance. RESULTS: Three of the previously proposed methods failed mainly because of zero-crossings of the IDIF. The remaining five methods were improved by calibration, yielding unbiased Km values. The method with the lowest SD yielded an SD of 0.0017/min--that is, below 10% of the muscle K(m) value in this study. CONCLUSION: Previously proposed IDIF methods can be improved by using a simple calibration procedure. The calibration procedure may be used in other studies, thus obviating the need for arterial blood sampling, once the calibration parameters have been established in a subgroup of participants. The method has potential for use in other parts of the body as it is robust with regard to partial volume effects.
No takes yet. Share an insight, caveat, or question.
Christensen et al. (2013) studied this question. Calibrated image-derived input functions (IDIFs) vs. Arterial blood samples was evaluated on Metabolic uptake rate of glucose (Km). Calibration of image-derived input function methods yielded unbiased metabolic uptake rate of glucose values without blood sampling, achieving a standard deviation as low as 0.0017/min.