PURPOSE: To compare results with the following magnetic resonance (MR) imaging sequences in the detection of focal hepatic lesions: fast spin-echo (SE) before and after administration of superparamagnetic iron oxide (SPIO) particles, fat-suppressed T2-weighted SE, and dynamic gadolinium-enhanced fast low-angle shot (FLASH). MATERIALS AND METHODS: In 26 patients with known malignancy and documented focal liver lesions, 1.0-T MR imaging was performed prior to hepatic resection. All images were reviewed independently by four blinded observers. Sensitivity was calculated for each sequence and for each observer by means of alternative-free-response receiver operating characteristic (ROC) methods. RESULTS: The mean area under the alternative-free-response ROC curve with SPIO-enhanced fast SE (0.85) was significantly greater (P < .02) than that with all other sequences. Detection was significantly improved with SPIO-enhanced fast SE compared with dynamic gadolinium-enhanced FLASH (which was the best of the other three sequences) for all lesions (P < .002) and for malignant lesions (P < .0002). CONCLUSION: Findings with the SPIO-enhanced fast SE sequence improved detection of focal liver lesions and had the highest diagnostic accuracy.
No takes yet. Share an insight, caveat, or question.
Blakeborough et al. (1997) studied this question.