Key result
Surveyed cardiac arrest investigators report that 60% use α-stat for ABG analysis during targeted hypothermia.
Why the study?
Two major cardiac arrest trials agreed to standardise ABG assessment by the α-stat method, prompting investigation into site investigators' self-reported practices and views on α-stat versus pH-stat assessment.
Cross-Sectional (n=70)
Yes
A survey of cardiac arrest trial investigators found that α-stat is the most common approach for ABG analysis during targeted temperature management, supporting its standardized use in clinical trials.
Answers are grounded in this paper and cite their sources.
Standardization to α-stat ABG analysis mitigates CO2 measurement bias across co-enrolled cardiac arrest trials; enables valid comparison of hypothermia and hypercapnia strategies.
Background: Two major cardiac arrest trials are evaluating different strategies that may potentially mitigate neurological injury after cardiac arrest and are allowing co-enrolment. However, one trial will target hypothermia and the other will target mild hypercapnia, in which the carbon dioxide (CO2) measurement may be influenced by the choice of temperature adjustment during arterial blood gases (ABGs) measurement. The trials have agreed to standardise assessment by the α-stat method. Objectives: To describe the Targeted Therapeutic Mild Hypercapnia after Resuscitated Cardiac Arrest (TAME) and Targeted Hypothermia versus Targeted Normothermia after Out-of-hospital Cardiac Arrest (TTM2) site investigators’ self-reported practice of ABG analysis and, in particular, their view of whether α-stat or pH-stat assessment of ABGs is considered optimal. Methods: We performed an online anonymous multichoice survey. Of the 136 site investigators emailed, 70 (51%) responded. Of these, 19 (27%) were participating in the TAME trial only, 22 (31%) were in TTM2 only, and 29 (41%) were participating in both. Results: The majority of respondents identified α-stat (41/68, 60%) compared with pH-stat (27/68, 40%) as their usual approach to ABG analysis when targeting 33°C. In addition, the proportion and pattern of concern over hyperventilation was similarly reported as either “not concerned” or “neutral” when using an α-stat (46/69, 66%) or pH-stat (50/68, 73%) ABG analysis approach. Finally, for the purpose of a randomised controlled trial, most respondents either “strongly agreed”, “agreed” or “neither agreed nor disagreed” to use the α-stat (59/69, 85%) or the pH-stat (61/70, 87%) approach. Conclusion: Our survey findings support the acceptability of the decision to apply the α-stat approach across participating sites for both trials.
No takes yet. Share an insight, caveat, or question.
Eastwood et al. (2019) conducted a cross-sectional in Cardiac arrest (investigator survey) (n=70). α-stat approach vs. pH-stat approach was evaluated on Usual approach to ABG analysis when targeting 33°C. Among surveyed cardiac arrest trial investigators, 60% reported using the α-stat approach and 40% used the pH-stat approach for arterial blood gas analysis when targeting 33°C.
Synapse has enriched 10 related papers. Consider them for comparative context: