Background: Comminuted femoral shaft fractures present significant technical challenges in restoring length, alignment, and rotation. We present a case in which a nail-Schanz pin integrated external distractor was used to facilitate length restoration, controlled reduction, and maintenance of alignment. Case presentation: A 36-year-old male sustained a high-energy comminuted femoral shaft fracture with extensive posterior degloving injury following a motorcycle accident. Closed reduction and statically locked intramedullary nailing were performed using a nail-Schanz pin integrated external distractor. Gradual distraction allowed restoration of femoral length, and fine corrections of alignment and rotation were performed using a distractor under fluoroscopic guidance. Results: Radiographic union was achieved at 9 months postoperatively. Final assessment demonstrated negligible limb length discrepancy (+7 mm), 3° varus coronal alignment, neutral sagittal alignment, and no clinically significant rotational malalignment. The patient demonstrated a normal, pain-free gait and regained full range of motion of the hip and knee. Conclusions: This case demonstrates that a nail-Schanz pin integrated external distractor can be a useful adjunct during intramedullary nailing of comminuted femoral shaft fractures, enabling precise restoration of length and stable maintenance of reduction.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: