Answers are grounded in this paper and cite their sources.
BACKGROUND: Single-port robot-assisted surgery represents the latest advancement in minimally invasive urological oncology. The SHURUI single-port (SP) surgical robot system recently received approval as a second SP system and as alternative to the Da Vinci platform. We report the first comparison of the two systems in radical cystectomy patients. METHODS: We conducted a retrospective comparative study at a tertiary referral center comparing operative and oncological outcomes in consecutive patients with bladder cancer who underwent single incision radical cystectomy using either the SHURUI SP-SR system or the Da Vinci Xi system. RESULTS: We treated eleven patients using the SHURUI SP-SR system and 24 patients using the Da Vinci Xi system. We successfully completed all procedures without conversion. Baseline characteristics were generally similar between groups, and short-term perioperative, postoperative recovery, complication, and pathological outcomes were broadly comparable. No unexpected safety concerns were identified. Study limitations include small sample size, single-surgeon experience, retrospective design, and short follow-up. CONCLUSIONS: We demonstrated that in the first experiences SHURUI SP achieves comparable perioperative safety and efficacy to Da Vinci Xi for single incision radical cystectomy. Our findings support SHURUI as a potential alternative, potentially expanding robotic surgery access.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: