Key result
Successful PTA is linked to a ~60% reduction in high-frequency flow motion waves.
Why the study?
The characteristics and prevalence of low and high frequency flow motion waves in severe ischaemia before and after PTA were not well understood.
Does percutaneous transluminal angioplasty alter the prevalence of low and high frequency flow motion waves in patients with severe ischaemia due to peripheral arterial occlusive disease?
Observational (n=18)
Does percutaneous transluminal angioplasty alter the prevalence of low and high frequency flow motion waves in patients with severe ischaemia due to peripheral arterial occlusive disease?
Absolute Event Rate: 36.4% vs 90.9%
p-value: p=<0.001
High frequency flow motion waves decrease after successful percutaneous transluminal angioplasty, suggesting they represent a compensatory microcirculatory reaction to severe ischaemia.
PTA-linked reduction in high-frequency waves supports compensatory ischemia marker role; leaves open prospective validation before clinical adoption.
UNLABELLED: STUDY OF OBJECTIVE: The aim was to evaluate skin flux and prevalence of low and high frequency flow motion waves in patients with severe ischaemia due to peripheral arterial occlusive disease before and after percutaneous transluminal angioplasty (PTA) with and without local thrombolysis. DESIGN: Flow motion was recorded by the laser Doppler technique at the dorsum of the foot before, one day, and one month after PTA. The results were separately analysed in patients with successful and unsuccessful treatment. SUBJECTS: 18 patients with rest pain or incipient gangrene were included. Mean pretreatment systolic ankle pressure was 55.8(SD 25.5) mm Hg, and mean transcutaneous PO2 at 43 degrees C was 5.2(9.4) mm Hg. Arteriography revealed relevant stenoses or occlusions of the femoropopliteal and calf arteries. MEASUREMENTS AND RESULTS: Before treatment two patterns of flow motion with characteristic frequency ranges were observed at the foot dorsum and at a probe temperature of 32 degrees C: low frequency (LF) waves with a mean frequency of 2.2(0.5) cycles.min-1 and a mean amplitude of 0.73(0.42) arbitrary units (AU) and high frequency (HF) waves with a mean frequency of 22.6(4.2) cycles.min-1 and a mean amplitude of 0.39(0.33) AU. PTA was successful in 11 of the 18 patients. After successful treatment, prevalence of HF waves decreased from 10/11 to 4/11 cases (p less than 0.001), but remained nearly unchanged after failed procedure. Prevalence of LF waves before and after PTA did not differ significantly. CONCLUSIONS: Our data support the hypothesis that HF waves represent a reaction of skin microcirculation to severe ischaemia. With reference to animal studies it is proposed that HF waves originate from terminal arterioles. They may function as a compensatory mechanism of flow regulation involved in pathophysiology of ischaemia.
No takes yet. Share an insight, caveat, or question.
Hoffmann et al. (1990) conducted an observational in Severe ischaemia due to peripheral arterial occlusive disease (n=18). Successful percutaneous transluminal angioplasty vs. Before treatment was evaluated on Prevalence of high frequency (HF) flow motion waves (p=<0.001). Successful percutaneous transluminal angioplasty significantly decreased the prevalence of high frequency flow motion waves from 90.9% to 36.4% (P<0.001).