In this study, we combined quantitative ultrashort echo time (UTE) magnetic resonance (MR) imaging and an investigation by a probing device with tri-axial force sensor to seek correlations with mechanical properties of human patellar cartilage for in situ evaluation of biomechanical properties. Cartilage blocks (15 × 20 × 5 mm3) were dissected from the patella of six donors; 5 mm square regions of interest from the cartilage blocks were imaged using UTE-MR imaging sequences (T2* and magnetization transfer ratio (MTR)), and mechanical properties were measured using a micro indentation device. Then, the vertical reaction force on the cartilage surface was measured while push-probing forward 3 mm with the probing device at a 30° tilt to the horizontal plane. The results showed a positive correlation between stiffness/elastic modulus and each predictor variable (UTE-T2* (r = 0.240 and 0.255, respectively, UTE-MTR (r = 0.378 and 0.379, respectively), and probing device force (r = 0.426 and 0.423, respectively). Furthermore, multiple linear regression analysis showed the combination of the three predictors had stronger correlation (adjusted r2 = 0.314 (stiffness), 0.323 (elastic), respectively). Our results demonstrate the potential for these non- and less- invasive methods for in situ evaluation of the mechanical properties of cartilage tissue.