Answers are grounded in this paper and cite their sources.
Novel designs and materials for filtering face-piece respirators (FFRs) have been disseminated in response to shortages during the COVID-19 pandemic. Since filtration efficiency depends on particle diameter and air face velocity, the relevance of material filtration or prototype fit data depends on test conditions. We investigate whether characterizing a material in a filter holder at a range of face velocities enabled precise prediction of the filtration performance of a novel sewn mask design. While larger particles (> 500 nm) are more relevant for inhalation exposure to respiratory emissions, we compare this mask and a N95 FFR (as a control) with smaller particles more similar to those in the N95 test method. Sewn from sterilization wrap, our mask (sealed to a mannequin head with silicone) filters 85 ± 1% of 136 nm particles (NaCl, 85 L min–1) and passes quantitative fit tests for 4 of 6 volunteers, representing intermediate protection between a surgical mask and N95 FFR. Filter holder material measurements overpredict the sewn mask’s filtration efficiency by 8.2% (95% CI 7.4–9.1%) (136 or 200 nm). While testing flat material in a filter holder enables comparison between materials, filtration performance does not precisely scale-up from filter holder to mannequin tests. Testing full prototypes at relevant conditions is crucial if an improvised design is intended as a substitute for a commercial surgical mask or FFR.
No takes yet. Share an insight, caveat, or question.
Dang et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: