Key result
Brief patient education boosts median SCD compliance by ~33% compared to baseline.
Why the study?
Patients admitted to trauma floors have poor compliance with sequential compression devices (SCDs) for mechanical venous thromboembolism prophylaxis.
Does a patient education intervention improve SCD compliance in trauma patients?
Does a patient education intervention improve SCD compliance in trauma patients?
Absolute Event Rate: 60% vs 45%
A patient education intervention modestly improved SCD compliance in trauma patients, but additional interventions addressing other barriers are likely needed.
Venous thromboembolism (VTE) is the fourth most commonly reported complication in trauma patients. For these patients, thromboprophylaxis is a standard of care. Patient compliance with sequential compression devices (SCDs), a form of mechanical VTE prophylaxis, has been a focus of efforts to improve patient safety. At our institution, a baseline audit in July 2020 revealed that patients admitted to the trauma floors have poor compliance with the use of SCDs. In this quality improvement project, we developed a patient education intervention to improve SCD compliance. We distributed an informational flyer to patients and led short educational sessions on VTE risk factors and proper SCD use. Our aim was to increase our SCD compliance rate by 30% in 4 weeks. We used three plan-do-study-act (PDSA) cycles to implement and refine our intervention. We measured SCD compliance during morning and afternoon patient observations and generated run charts to understand how our cycles were leading to change. After a 4-week period, we did not achieve our aim, but increased our overall compliance from 45% to 60% and sustained this improvement throughout our PDSA cycles. Morning compliance was lower than afternoon compliance both at baseline (45% vs 48.5%) and at the end the project (45% vs 53%). Our results suggest that patient education should be coupled with interventions that address other barriers to SCD compliance.
No takes yet. Share an insight, caveat, or question.
Hamid et al. (2021) studied Trauma (n=471). Patient education intervention (informational flyer and educational sessions) vs. Baseline (pre-intervention) was evaluated on Sequential compression device (SCD) compliance rate. A patient education intervention consisting of an informational flyer and short educational sessions increased the overall median sequential compression device compliance rate from 45% to 60%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: