Key result
Trainee-performed Mini-AVR takes ~12 extra bypass minutes vs attendings but maintains similar safety.
Why the study?
Minimally invasive aortic valve replacement is technically advanced, and the impact of trainee performance on short-term outcomes was unclear.
Does minimally invasive aortic valve replacement performed by trainees compromise short-term safety outcomes compared to attending surgeons in patients undergoing elective and urgent Mini-AVR?
Cohort (n=205)
Does minimally invasive aortic valve replacement performed by trainees compromise short-term safety outcomes compared to attending surgeons in patients undergoing elective and urgent Mini-AVR?
Trainees can safely perform minimally invasive aortic valve replacement with comparable short-term clinical outcomes to attending surgeons, despite slightly longer operative times.
Answers are grounded in this paper and cite their sources.
Supports supervised trainee Mini-AVR; leaves open validation in randomized or higher-risk cohorts.
OBJECTIVES: Minimally invasive aortic valve replacement (Mini-AVR) is a technically advanced procedure. However, it results in equivalent operative mortality, less bleeding and reduced intensive care/hospital stay when compared with conventional AVR. Our aim was to assess the impact of trainee performance on short-term outcomes of patients undergoing elective and urgent Mini-AVR where a significant proportion were performed by trainees. METHODS: All patients undergoing non-emergency, elective and urgent, isolated Mini-AVR between September 2005 and December 2012 were studied. Operative details and short-term outcomes, with particular attention to trainee performance, were analysed. RESULTS: During the study period, there were 205 Mini-AVR with a median age of 67 years (range 29-86); 74 (36%) operations were performed by trainees. The overall median cross-clamp and bypass times were 42 (range 33-63) and 59 min (range 59-94) for the attending surgeon and 52 (range 42-63) and 71 min (range 59-94) for the trainee (P = 0.03). Five Mini-AVR patients (2.4%) required conversion to full sternotomy for ascending aortic replacement, right ventricular bleeding, coronary artery bypass graft surgery and failure to cardiovert. None of these cases were performed by trainees. Median lengths of intensive care and hospital stay were 1 and 5 days and were not different for attending surgeon and trainee. Only 1 (0.5%) patient died in hospital. CONCLUSIONS: Mini-AVR can be performed with a low conversion rate and hospital stay and taught to trainees without compromising safety.
No takes yet. Share an insight, caveat, or question.
Soppa et al. (2015) conducted a cohort in Patients undergoing elective and urgent minimally invasive aortic valve replacement (n=205). Mini-AVR performed by trainees vs. Mini-AVR performed by attending surgeons was evaluated on Cross-clamp and bypass times (p=0.03). Minimally invasive aortic valve replacement by trainees had longer median cross-clamp (52 vs 42 min) and bypass times (71 vs 59 min; P=0.03) than attendings, but similar length of stay and safety.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: