Answers are grounded in this paper and cite their sources.
In recent years many investigators have used thermoelectric heat‐flow transducers to measure heat conduction in natural soil. If the transducer has thermal properties different from those of the soil it will interfere with the natural heat transfer and an error in measurement will occur. An analysis of the error for a transducer placed in an infinite medium in steady‐state conditions is made in terms of two non‐dimensional parameters: (1) the ratio of transducer conductivity to soil conductivity, and (2) the ratio of transducer thickness to transducer width. An exponential relationship is postulated on the basis of physical considerations and is verified by the results of an electrical analogy experiment for a square transducer having a thickness‐width ratio of 0.125 for conductivity ratios from about 0.1 to 2.2. An error of −70 pct was found for a conductivity ratio of 0.1 and an error of +5 pct for a conductivity ratio of 2.2. The results are used to estimate error in measurements made during the Great Plains Turbulence Field Program.
No takes yet. Share an insight, caveat, or question.
Donald J. Portman (1958) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: