The levels of anti-tetanus toxoid IgG antibodies were measured in 29 lots of intravenous gamma globulin (IVIG). The antibody levels varied from 4 to 90 IU/mL (geometric mean, 18.6; 90% confidence interval, 9.7-35.7). The variation from manufacturer to manufacturer accounted for most of the observed differences among lots; there was relatively little variability among multiple lots from a single manufacturer. IVIG may be an acceptable alternative to horse or human tetanus immune globulin.
No takes yet. Share an insight, caveat, or question.
Lee et al. (1992) studied this question.