Answers are grounded in this paper and cite their sources.
Values of thermal contact resistance are reported for two types of joints: (1) the joint between two blocks of laminated steel, either in direct contact or separated by cement or shims of steel, aluminum, or aluminum foil; (2) the joint between two blocks of cold-rolled steel with various surface finishes. The resistance as measured amounts to 0.3 to 8 in. of additional material, depending upon the configuration. Results are also given in terms of contact resistance.
No takes yet. Share an insight, caveat, or question.
Brunot et al. (1949) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: