Answers are grounded in this paper and cite their sources.
Experimental study demonstrates reversible temperature-dependent current modulation on gel-modified platinum electrodes, suggesting new sensor capabilities in electroanalysis.
Thin layers of the thermo sensitive cross‐linked poly(N‐isopropylacrylamide) gel were anchored on the surface of platinum micro‐ and regular‐electrodes. No preliminary functionalization of the surface was used; just electroformation of radicals at the surface led to strong binding of the polymer net. The electroanalytical investigation was focused on how the volume phase transition affects the height of the voltammetric peak of a model compound, 1,1′‐ferrocenedimethanol. The changes in the oxidation peak current of the electroactive compound upon switching temperature were perfectly reversible. Additionally, it was found that these changes were very fast and the polymer film was very stable. Very good adhesion of poly(N‐isopropylacrylamide) gel to platinum surface and excellent reversibility of the shrinking/swelling process (volume phase transition) may produce new possibilities in electroanalysis.
No takes yet. Share an insight, caveat, or question.
Karbarz et al. (2012) studied this question.