Key result
Most heart failure patients accept up to ~9% device-associated mortality risk for improved physical function.
Why the study?
Regulatory and clinical decisions involving health technologies require judgements about relative importance of expected benefits and risks, prompting a need to quantify heart failure patients' acceptance of therapeutic risks for improved device effectiveness.
What is the maximum acceptable risk of mortality that heart failure patients are willing to accept for improved physical functioning from an implantable device?
Cross-Sectional (n=613)
randomized to one of 40 blocks of 8 experimentally controlled choice questions
Yes
What is the maximum acceptable risk of mortality that heart failure patients are willing to accept for improved physical functioning from an implantable device?
Effect estimate: 9% absolute risk (95% CI 7-11)
Heart failure patients exhibit heterogeneous risk tolerance for implantable devices, with a majority willing to accept up to 9% mortality risk for significant functional improvement.
Preferences vary widely in device decisions; hypothesis-generating for preference-informed counseling pending prospective validation.
BACKGROUND: Regulatory and clinical decisions involving health technologies require judgements about relative importance of their expected benefits and risks. We sought to quantify heart-failure patients' acceptance of therapeutic risks in exchange for improved effectiveness with implantable devices. METHODS: Individuals with heart failure recruited from a national web panel or academic medical center completed a web-based discrete-choice experiment survey in which they were randomized to one of 40 blocks of 8 experimentally controlled choice questions comprised of 2 device scenarios and a no-device scenario. Device scenarios offered an additional year of physical functioning equivalent to New York Heart Association class III or a year with improved (ie, class II) symptoms, or both, with 30-day mortality risks ranging from 0% to 15%, in-hospital complication risks ranging from 0% to 40%, and a remote adjustment device feature. Logit-based regression models fit participants' choices as a function of health outcomes, risks and remote adjustment. RESULTS: Latent-class analysis of 613 participants (mean age, 65; 49% female) revealed that two-thirds were best represented by a pro-device, more risk-tolerant class, accepting up to 9% (95% CI, 7%-11%) absolute risk of device-associated mortality for a one-year gain in improved functioning (New York Heart Association class II). Approximately 20% were best represented by a less risk-tolerant class, accepting a maximum device-associated mortality risk of 3% (95% CI, 1%-4%) for the same benefit. The remaining class had strong antidevice preferences, thus maximum-acceptable risk was not calculated. CONCLUSIONS: Quantitative evidence on benefit-risk tradeoffs for implantable heart-failure device profiles may facilitate incorporating patients' views during product development, regulatory decision-making, and clinical practice.
No takes yet. Share an insight, caveat, or question.
Reed et al. (2021) conducted a cross-sectional in heart failure (n=613). Implantable device scenarios vs. No-device scenario was evaluated on Maximum acceptable absolute risk of device-associated mortality for a one-year gain in improved functioning (9% absolute risk, 95% CI 7-11). Two-thirds of heart failure patients accepted up to a 9% (95% CI, 7-11%) absolute risk of device-associated mortality for a one-year gain in improved functioning in a discrete-choice experiment.