Key result
Clinical nurse coding of ACS-NSQIP colorectal resections shows low inter-rater reliability.
Why the study?
Inconsistent assignment of CPT codes in ACS-NSQIP colorectal procedures may affect benchmarking and risk prediction accuracy.
Cross-Sectional (n=44)
Yes
There is low inter-rater reliability in the coding of ACS-NSQIP colorectal resection procedures among trained reviewers in Canada, which translates to significant variation in risk prediction.
Answers are grounded in this paper and cite their sources.
Low ACS-NSQIP coding reliability cautions reliance on these data for colorectal risk prediction; leaves open needs for standardized validation in surgical registries.
The American College of Surgeons National Surgical Quality Improvement Project (ACS-NSQIP) collects risk-adjusted surgical data utilizing Current Procedural Terminology (CPT) codes. Inconsistent code assignment may affect benchmarking calculations. This study aims to assess inter-rater reliability of coding colorectal resection procedures across Canada by ACS-NSQIP surgical clinical nurse reviewers (SCNR) and the impact on risk predictions. An electronic survey was distributed to Canadian SCNRs, asking them to assign CPT codes to simulated synoptic operative reports. Percent agreement and free-marginal kappa correlation were calculated. The ACS-NSQIP risk calculator was used to compare predicted morbidity and mortality between the two most frequently chosen codes for each case, to demonstrate impact on risk prediction. 44 of 150 (29.3%) survey recipients responded. There was significant variability in the CPT codes chosen. Agreement ranged from 6.7% 62.3%. Free-marginal kappa correlation ranged from moderate agreement (0.53) to high disagreement (-0.17). The ACS-NSQIP risk calculator predicted absolute differences in risk of serious complications and mortality ranging from 0.2–13.7% and 0.2–6.3%, respectively. This study demonstrated low inter-rater reliability in the coding of ACS-NSQIP colorectal resection procedures in Canada among trained SCNRs. The resulting coding inconsistency translated to variation in risk prediction.
No takes yet. Share an insight, caveat, or question.
Xiong et al. (2023) conducted a cross-sectional in ACS-NSQIP colorectal procedure coding (n=44). CPT coding of simulated colorectal operative reports was evaluated on Inter-rater reliability (percent agreement and free-marginal kappa correlation) (Agreement 6.7%-62.3%, kappa -0.17 to 0.53). Coding of ACS-NSQIP colorectal resection procedures by Canadian surgical clinical nurse reviewers showed low inter-rater reliability, with agreement ranging from 6.7% to 62.3%.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: