Answers are grounded in this paper and cite their sources.
Method validation study demonstrates precise and accurate quantification of pentoxifylline in tablet formulations, indicating suitability for routine pharmaceutical quality control.
Selective and simple reversed phase High Performance Liquid Chromatography (RP-HPLC) method was developed and validated for quantification of pentoxifylline in dosage forms available in local market. Firstly, different chromatographic conditions were tested. Then, the optimized method was validated. The method proven to be linear over 50% to 150% of the nominal concentration of standard pentoxifylline (R2 0.994). The method was accurate (recovery 100.1%) and precise (RSD% <3%). The method could separate pentoxifylline of caffeine and degradation products. The method was suitable for routine analysis of pentoxifylline in tablet dosage forms.
No takes yet. Share an insight, caveat, or question.
N.K. Thallaj (2022) studied this question.