Key result
Advancing gestational age correlates with a ~0.15 mm weekly increase in mitral valve-tricuspid valve distance.
Why the study?
The normal distance between the medial leaflets of the mitral and tricuspid valves in the fetal heart and its variation with gestational age was not quantified to aid identification of Ebstein anomaly.
Observational (n=145)
Answers are grounded in this paper and cite their sources.
Establishes a reference range for normal fetal mitral valve-tricuspid valve distance, which increases with gestational age and can help identify Ebstein anomaly.
OBJECTIVE: To quantify the normal distance between the insertion of the medial leaflets of the mitral valve and tricuspid valve in the fetal heart. This mitral valve-tricuspid valve distance was compared with the distance from known cases of Ebstein anomaly. METHODS: An apical 4-chamber view was obtained at end diastole in fetuses between 18 and 41 weeks' gestation. Calipers were placed parallel to the ventricular septum, with 1 caliper on the medial insertion of the mitral valve and a second caliper on the medial insertion of the tricuspid valve. The distance recorded was plotted against gestational age. Statistical analysis was performed by descriptive and linear regression techniques. RESULTS: One hundred forty-five fetuses were studied. The mean +/- SD mitral valve-tricuspid valve distance in the second trimester was 2.8 +/- 0.9 mm with a range of 1.2 to 5.0 mm; in the third trimester it was 4.6 +/- 1.1 mm with a range of 2.2 to 6.9 mm. Regression analysis showed that with each 1-week increase in gestational age, there was an increase of 0.15 mm in separation between the medial leaflets of the mitral valve and tricuspid valve (beta = 0.15 +/- 0.011). CONCLUSIONS: A positive correlation between mitral valve-tricuspid valve distance and advancing gestational age was found. The reference range described allows for the identification of a fetal heart with normal variation in the mitral valve-tricuspid valve distance. Further downward displacement of the medial tricuspid cusp suggests the possibility of Ebstein anomaly.
No takes yet. Share an insight, caveat, or question.
Vettraino et al. (2002) conducted an observational in Normal fetal heart development (n=145). Gestational age was evaluated on Mitral valve-tricuspid valve distance (beta = 0.15 +/- 0.011). Advancing gestational age was positively correlated with mitral valve-tricuspid valve distance, increasing by 0.15 mm per week.
Synapse has enriched 10 related papers. Consider them for comparative context: