Key result
R-CEPIA1er measures SR calcium dynamics as effectively as Fluo5-N but avoids dye extrusion and photobleaching.
Why the study?
Direct measurement of sarcoplasmic reticulum calcium concentration in ventricular myocytes was limited by nonspecific localization, dye extrusion, and species limitations of existing low-affinity Ca indicators.
R-CEPIA1er is a reliable, genetically encoded calcium indicator for directly measuring sarcoplasmic reticulum calcium dynamics in ventricular myocytes without the limitations of traditional dyes.
Answers are grounded in this paper and cite their sources.
May improve SR Ca imaging in animal myocytes without dye limitations; leaves open validation in intact hearts or humans.
In cardiomyocytes, [Ca] within the sarcoplasmic reticulum (SR; [Ca]SR) partially determines the amplitude of cytosolic Ca transient that, in turn, governs myocardial contraction. Therefore, it is critical to understand the molecular mechanisms that regulate [Ca]SR handling. Until recently, the best approach available to directly measure [Ca]SR was to use low-affinity Ca indicators (e.g., Fluo-5N). However, this approach presents several limitations, including nonspecific cellular localization, dye extrusion, and species limitation. Recently a new genetically encoded family of Ca indicators has been generated, named Ca-measuring organelle-entrapped protein indicators (CEPIA). Here, we tested the red fluorescence SR-targeted Ca sensor (R-CEPIA1er) as a tool to directly measure [Ca]SR dynamics in ventricular myocytes. Infection of rabbit and rat ventricular myocytes with an adenovirus expressing the R-CEPIA1er gene displayed prominent localization in the SR and nuclear envelope. Calibration of R-CEPIA1er in myocytes resulted in a Kd of 609 μM, suggesting that this sensor is sensitive in the whole physiological range of [Ca]SR [Ca]SR dynamics measured with R-CEPIA1er were compared with [Ca]SR measured with Fluo5-N. We found that both the time course of the [Ca]SR depletion and fractional SR Ca release induced by an action potential were similar between these two Ca sensors. R-CEPIA1er fluorescence did not decline during experiments, indicating lack of dye extrusion or photobleaching. Furthermore, measurement of [Ca]SR with R-CEPIA1er can be combined with cytosolic [Ca] measurements (with Fluo-4) to obtain more detailed information regarding Ca handling in cardiac myocytes. In conclusion, R-CEPIA1er is a promising tool that can be used to measure [Ca]SR dynamics in myocytes from different animal species.
No takes yet. Share an insight, caveat, or question.
Bovo et al. (2016) studied this question. R-CEPIA1er vs. Fluo5-N was evaluated on Sarcoplasmic reticulum calcium dynamics (time course of depletion and fractional SR Ca release). R-CEPIA1er effectively measures sarcoplasmic reticulum calcium dynamics in ventricular myocytes, demonstrating similar performance to Fluo5-N but without dye extrusion or photobleaching.
Synapse has enriched 10 related papers. Consider them for comparative context: