Key result
In a general population sample, the photoplethysmographic pulse wave amplitude hyperaemic response was significantly higher in women than men (P<0.001) and decreased with higher blood pressure (P<0.03).
Why the study?
Previous studies mainly used fingertip tonometric devices to measure pulse wave amplitude changes after reactive hyperaemia, but the correlates of photoplethysmographic PWA responses as a measure of peripheral vascular function were not well evaluated.
What are the determinants of photoplethysmographic pulse wave amplitude hyperemic changes in a population sample?
Cross-Sectional (n=63)
No
What are the determinants of photoplethysmographic pulse wave amplitude hyperemic changes in a population sample?
Photoplethysmography measurement of the hyperemic response is a useful tool for detecting endothelial dysfunction associated with higher blood pressure and male gender.
Answers are grounded in this paper and cite their sources.
PPG PWA hyperaemia offers a feasible alternative measure of peripheral vascular function; leaves open standardization and prognostic validation.
Background: Vasodilation of the peripheral arteries after reactive hyperaemia depends in part on the release of nitric oxide from endothelial cells.Previous studies mainly employed a fingertip tonometric device to derive pulse wave amplitude (PWA) and, therefore, measure PWA hyperaemic changes.Another approach to derive information about PWA is based on photoplethysmography (PPG).We sought to evaluate the correlates of digital PPG PWA hyperaemic responses as a measure of peripheral vascular function.Methods: Using a fingertip PPG device, we measured digital PWA in 63 subjects enrolled in a population study (55.5% women; mean age, 55 years; 58.7% hypertensive) at baseline and at 30-s intervals for 4 min during reactive hyperaemia induced by a 5-min forearm cuff occlusion.We performed stepwise regression to identify correlates of the hyperaemic response ratio for each 30-s interval after cuff deflation.Results: With age forced into the models, the explained variance for the PPG PWA ratio totalled from 17.1% at the 210e240-s time interval to 31.3% at 30e60-s time interval.The hyperaemic response at each 30-s interval was significantly higher in women compared to men (P < 0.001).The PPG PWA changes at 0e60-s intervals decreased with higher blood pressure (BP) (P < 0.03).These associations with sex and systolic BP were mutually independent.Conclusions: Our study described in a population sample the determinants of PPG PWA hyperaemic changes.We demonstrated that measurement of the hyperaemic response by PPG might be a useful tool in the detection of endothelial dysfunction associated with higher BP and male gender.
No takes yet. Share an insight, caveat, or question.
Kuznetsova et al. (2011) conducted a cross-sectional in General population (n=63). Higher blood pressure and male sex vs. Lower blood pressure and female sex was evaluated on Photoplethysmographic pulse wave amplitude (PPG PWA) hyperaemic response ratio (p=<0.001). In a general population sample, the photoplethysmographic pulse wave amplitude hyperaemic response was significantly higher in women than men (P<0.001) and decreased with higher blood pressure (P<0.03).