Answers are grounded in this paper and cite their sources.
Medium‐frequency transformers play a crucial role in providing galvanic isolation, yet their compact design presents challenges related to insulation and cooling. This study presents a versatile transient thermal circuit model specifically designed for shell‐type medium‐frequency transformers. The model effectively incorporates factors such as dielectric losses, various insulation materials, heatsink configurations and air gap influences, enhancing its adaptability for different medium‐frequency transformer designs without requiring modifications to the thermal circuit. Validation of the model was performed using measurements from a 5 kW, 20 kHz dual‐active bridge testbench with a solid‐insulated medium‐frequency transformer prototype, as well as data from a thermal analysis of a 100 kW, 10 kHz air‐insulated medium‐frequency transformer sourced from existing literature. When comparing the model results to measurements across all the investigated medium‐frequency transformer designs and scenarios, the relative error in hotspot temperature at nominal load during steady‐state did not exceed 7.1%, while the average relative root mean square error in hotspot temperature during the transient state (from no load to nominal load) was below 8.3%. These results confirm the model's accuracy and its broad applicability for transient thermal analysis of shell‐type medium‐frequency transformers.
No takes yet. Share an insight, caveat, or question.
Meligy et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: