Answers are grounded in this paper and cite their sources.
Ohmic heating has emerged as an effective alternative to conventional thermal treatments for fruit juice preservation. However, the performance of an ohmic heating system is strongly influenced by the excitation waveform generated by its power electronics circuitry. Conventional systems typically employ square‐wave excitation, which can produce rapid temperature rises and may adversely affect nutrient retention. There is therefore a need for alternative excitation waveforms that provide better control over the temperature rise while maintaining effective microbial inactivation. To address this need, this work proposes a novel ohmic heating system comprising a custom‐designed square‐wave generator and an RC differentiator that converts the square‐wave output into exponentially decaying pulses. The square‐wave generator is designed to deliver the voltage and current levels required for juice treatment, and the RC differentiator enables controlled energy delivery to the load by optimising the pulse width. The proposed circuit produces high‐amplitude, short‐duration exponential pulses with a peak electric field intensity of 140 V/cm and an optimised pulse width of 46 μ s. The treatment system was analysed and experimentally validated using watermelon juice as the treatment medium. Experiments were conducted with electrode gaps ranging from 5 mm to 20 mm, operating frequencies of 1 kHz and 10 kHz and a maximum treatment temperature of 70°C. The influence of the generated exponential pulses on treatment performance was evaluated through microbial inactivation studies with Escherichia coli and nutrient retention measurements of vitamin C and total antioxidant activity. Experimental results showed that with the maximum treatment temperature limited to 70°C, the optimised differentiator‐based system achieved a bacterial log reduction of 5.98 after 2.5 min, compared with 3.92 for the conventional square wave–driven system after 0.5 min. The proposed excitation method also maintained good nutrient retention characteristics while operating below 70°C. The results suggest that differentiator‐based pulse shaping can improve the effectiveness of ohmic heating systems and highlight the potential of customised waveform‐generation techniques for electric field–based food processing applications.
No takes yet. Share an insight, caveat, or question.
Mohan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: