Changes in cell performance with operation time were investigated for commercial cells possessing a composite cathode modified by nanostructured La 0.6 Sr 0.4 CoO 3-δ (LSCo). The electrocatalyst was introduced into a porous scaffold composed of Sm 2 O 3 -doped CeO 2 (SDC) and La 1-x Sr x Co y Fe 1-y O 3-δ (LSCF) by solution infiltration, which decreased polarization resistance (R p ) of baseline cells by 20-35%. R p of both a baseline cell and an infiltrated cell increased as the operation progressed for 1,500 h, while obeying a parabolic power law and showing 65% of total increase in the initial 150 hours. The degradation rate of the infiltrated cell was statistically indistinguishable from that of the baseline cell, implying that there was no measurable negative effect of infiltrated electrocatalysts on the cells’ time-dependent performance for the systems studied here. The stability of the infiltrated cathode was affirmed by multiple samples tested for 200 hours. AC impedance spectra analysis demonstrated that degradation of cathode activity would be the critical mechanism affecting long-term stable performance for both baseline cells and infiltrated cells.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: