Answers are grounded in this paper and cite their sources.
We investigated, at temperature 4.2 K, electric transport, flux noise, and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions with HfTi barriers. The SQUIDs are either of the magnetometer-type or gradiometric in layout. In the white noise regime, for the best magnetometer we obtain a flux noise SΦ1/2=250nΦ0/Hz1/2, corresponding to a spin sensitivity Sμ1/2≥29μB/Hz1/2. For the gradiometer we find SΦ1/2=300nΦ0/Hz1/2 and Sμ1/2≥44μB/Hz1/2. The devices can still be optimized with respect to flux noise and coupling between a magnetic particle and the SQUID, leaving room for further improvement towards single spin resolution.
No takes yet. Share an insight, caveat, or question.
A 2011 study studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: