Answers are grounded in this paper and cite their sources.
Fracture toughness testing standards such as ASTM E1820 or ASTM E 1921 ISO 12350 are seldom used in practice. Estimates of K Ic or J Ic by empirical correlations with classical Charpy impact tests are much more popular and often preferred. The reasons for this unsatisfying situation is that the standard procedures of fracture toughness testing are much more demanding than the Charpy test, in terms of costs, test material, test equipment and expertise of the laboratory personal, whereas the much simpler CV-test still delivers useful estimates. However, between standard fracture toughness testing and classical Charpy impact testing there is a wide space for possible new tests that are similarly simple as Charpy tests and similarly informative as a fracture toughness tests. In the present paper, some suggestions for such more practical fracture toughness tests are made.
No takes yet. Share an insight, caveat, or question.
Hans-Jakob Schindler (2018) studied this question.